11 Results for the search " induced":
Author: n.sene
Type: Publication
Date: 2015-04-01
Correlation of lightning events and faults in distribution power networks
Description:
The paper deals with the analysis of the possible correlation between cloud-to-ground lightning discharges and relay operations inferred by using the experimental data obtained means of a measurement ... see moreset-up, installed on an Italian MV distribution network, and a statistical procedure based on the coordinated use of the Italian Lightning Location System (LLS) CESI-SIRF, the monitoring systems of protection manoeuvres and an advanced simulation tool for the calculation of lightning induced overvoltages. The procedure takes into account the uncertainties related to the estimation of lightning stroke location and current amplitude provided by the LLS. The experimental set-up, composed by a distributed monitoring system, is able to measure a-periodic voltage transients characterized by a frequency content up to 4 MHz. Three of these units have been installed in the feeder of a three-phase overhead distribution network with a total length of 21 km. The same feeder is protected with overcurrent and zero-sequence relays whose operations are recorded by a monitoring system with a 10-ms sampling time. The data collected during one year of operation of the experimental set-up have been analyzed together with the data collected by the LLS for a 144 km2 area covering the equipped feeder and its surrounding area, in order to account for all direct and indirect lightning events that may have caused a relay intervention. The data have been also used to test the calculation model. The paper eventually reports the results of the correlation analysis carried out using the mentioned procedure, which is used to evaluate the probability that a specific event, detected by the LLS and time-correlated to relay operation, may have been the cause of a flashover in the network.
Authors: A. Borghetti, F. Napolitano, C.A. Nucci, M. Paolone, M. Bernardi, F. Rachidi, K. Yamabuki
CIGRE 2008 - a joint research project
Tag(s): Lightning protection, lightning-to-fault correlation, lightning location systems, lightning performance of distribution lines, induced overvoltages, a-periodic voltage transient measurement, EMTP.
Author: n.sene
Type: Publication
Date: 2015-04-01
Lightning-Induced Overvoltages Transferred Through Distribution Power Transformers
Description:
This paper deals with the calculation of lightning induced overvoltages on medium-voltage (MV) and low-voltage (LV) distribution networks taking into account the presence of MV–LV distribution trans... see moreformers and, in particular, the surge transfer through them. The influence of the high-frequency model adopted for the representation of the power transformer on the calculation results is analyzed, with regards to two different models, both identified and validated by means of laboratory measurements: namely, a simple π of capacitances, and the more complex one introduced by Morched, Marti, and Ottevangers in 1993. Accurate simulation results provide information on the adequacy of both models for the calculations of interest. Additional results, useful to evaluate the expected level of power quality and the benefits achievable by a proper installation of protection devices, are presented making reference to a realistic and complex configuration of an overhead distribution system
Authors: Alberto Borghetti, Atef Morched, Fabio Napolitano, Carlo Alberto Nucci, Mario Paolone,
IEEE TRANSACTIONS ON POWER DELIVERY, VOL. 24, NO. 1, JANUARY 2009
Tag(s): Lightning, distribution transformers, overvolatges
Author: n.sene
Type: Publication
Date: 2015-04-01
Interaction Between Grounding Systems and Nearby Lightning for the Calculation of Overvoltages in Overhead Distribution Lines
Description:
The aim of the paper is to analyze overvoltages in overhead distribution lines induced by nearby lightning return stroke currents taking into account also the conductive coupling between the lightning... see more current injected into the soil and the line’s grounding system. Experimental results obtained in 2003 at the International Center for Lightning Research and Testing (ICLRT) in Florida have shown that significant currents were coupled with an overhead experimental line through its grounding system by nearby rocket-triggered lightning.
The paper first proposes a conductive coupling model between the lightning current injected into the soil and the nearby line grounding system, then presents the incorporation of such a model into the LIOV-EMTP computer code. The paper finally presents an experimental validation of the proposed models by making reference to results obtained during the above-mentioned triggered-lightning campaign.
Authors: F. Napolitano, M. Paolone, A. Borghetti, C.A. Nucci, F. Rachidi, V.A. Rakov, J. Schoene and M. A. Uman
Tag(s): lightning induced overvoltages, grounding systems, overhead distribution lines, lightning protection.
Author: n.sene
Type: Publication
Date: 2015-04-01
Protection Systems Against Lightning-Originated Overvoltages in Resonant Grounded Power Distribution Systems
Description:
A joint research project between AES Sul, the Federal University of Itajubá and the University of Bologna aims at defining the required protections against lightning-originated overvoltages in a reso... see morenant grounded distribution system in order to achieve the adequate lightning performance level with minimum cost. The paper aims at illustrating the effectiveness of the presence of a surge arrester or spark gap and their protective zone by means of simulations obtained with a computer code for the calculation of lightning induced voltages that takes also into account the steady-state voltage. The results of a statistical analysis for a single multiconductor line are eventually presented and discussed.
Authors: A. Borghetti, F. Napolitano, C.A. Nucci, M.L.B. Martinez, G.P. Lopes, J.I.L. Uchoa
2012 International Conference on Lightning Protection (ICLP), Vienna, Austria
Tag(s): Lightning protection, power distribution networks, induced overvoltages.
Author: n.sene
Type: Publication
Date: 2015-04-01
Assessment of the Lightning Performance of Compact Overhead Distribution Lines
Description:
The assessment of the lightning performance of a compact configuration of MV overhead lines that is expected to be adopted in the near future by an electricity distribution company in a Brazilian regi... see moreon characterized by high keraunic levels is presented. The compact configuration is characterized by the presence of an unenergized wire that has the main function to sustain the spacers of the phase conductors. As the wire could be periodically grounded, the paper analyses its effectiveness in reducing the overvoltages due to indirect lightning. The results are compared with those relevant to a conventional configuration of MV overhead lines now adopted by the same distribution company. The effects of the presence of surge arresters along the line are also analysed.
Authors: F. Napolitano, A. Borghetti, D. Messori, C.A. Nucci, M.L.B. Martinez, G.P. Lopes, J.I.L. Uchoa
CIGRE SC C4 2012 Hakodate Colloquium
Tag(s): Lightning protection, Overhead distribution lines, Induced overvoltages, Electromagnetic transients.